<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Comparison of different formulas for intraocular lens power calculation using a new optical biometer

dc.authorid0000-0002-0972-3833
dc.authorid0000-0002-2267-6656
dc.contributor.authorKaya, Faruk
dc.contributor.authorKoçak, İbrahim
dc.contributor.authorAydın, Ali
dc.contributor.authorBaybora, Hakan
dc.contributor.authorKarabela, Yunus
dc.date.accessioned2020-06-26T08:33:18Z
dc.date.available2020-06-26T08:33:18Z
dc.date.issued2015
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalı
dc.description.abstractPurpose. - To evaluate and compare the predictability of different formulas for intraocular lens (IOL) power calculation using a new optical biometer (Aladdin). Methods. - This prospective cross-sectional study included 70 eyes of 70 patients who underwent uneventful phacoemulsification with IOL implantation. Preoperative IOL power calculations were performed using the Aladdin optical biometer. Postoperative actual refractive errors and errors predicted by the SRK/T, SRK II, Holladay 1, Hoffer Q and Haigis formulas were analyzed. The mean estimation error (EE), mean absolute estimation error (AEE) and the percentage of eyes within +/- 0.50 and +/- 1.00 D of the target refraction for each of five formulas were calculated and compared. This analysis was also repeated in three groups formed based on axial length (AL) (group 1: <22.5 mm, group 2: 22.5-24 mm, group 3: > 24 mm). Results. - In the overall study group, the smallest mean AEE was provided by the Holladay 1 formula, however there was no statistically significant difference in the mean AEE's predicted by the five formulas (P = 0.34). The highest percentage of eyes within +/- 0.50 and +/- 1.00 D of the target refraction was also found by using Holladay 1 (71% and 97%). SRK/T provided smallest mean AEE for groups 1 (n = 13) and 3 (n = 16). In group 2 (n = 41), the smallest mean AEE was obtained using Holladay 1. Conclusions. - Based on the Aladdin biometric data used in our study, better results can be obtained using SRK/T formula in eyes with short or long AL. The Holladay 1 formula may be preferred in eyes with moderate AL.
dc.identifier.citationKaya, F., Koçak, İ., Aydın, A., Baybora, H. ve Karabela, Y. (2015). Comparison of different formulas for intraocular lens power calculation using a new optical biometer. Journal Francais D Ophtalmologie, 38(8), 717-722. https://dx.doi.org/10.1016/j.jfo.2015.03.006
dc.identifier.doi10.1016/j.jfo.2015.03.006
dc.identifier.endpage722
dc.identifier.issn0181-5512
dc.identifier.issn1773-0597
dc.identifier.issue8
dc.identifier.scopusqualityQ3
dc.identifier.startpage717
dc.identifier.urihttps://dx.doi.org/10.1016/j.jfo.2015.03.006
dc.identifier.urihttps://hdl.handle.net/20.500.12511/5320
dc.identifier.volume38
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMasson Editeur
dc.relation.ispartofJournal Francais D Ophtalmologieen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectComparison
dc.subjectFormulas
dc.subjectBiometer
dc.titleComparison of different formulas for intraocular lens power calculation using a new optical biometer
dc.typeArticle

Files

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: