The comparison between the results of turbidimetric method for c-reactive protein measurement using different instruments
| dc.contributor.author | Uca, Erkan | |
| dc.contributor.author | Hacıhasanoğlu Çakmak, Neziha | |
| dc.contributor.author | Yiğitbaşı, Türkan | |
| dc.date.accessioned | 2025-10-27T09:03:08Z | |
| dc.date.available | 2025-10-27T09:03:08Z | |
| dc.date.issued | 2024 | |
| dc.department | İstanbul Medipol Üniversitesi, İMÜ Meslek Yüksekokulu, Tıbbi Laboratuvar Teknikleri Ana Bilim Dalı | |
| dc.department | İstanbul Medipol Üniversitesi, Sağlık Bilimleri Enstitüsü | |
| dc.department | İstanbul Medipol Üniversitesi, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü, Tıbbi Biyokimya Ana Bilim Dalı | |
| dc.description.abstract | C-reactive protein (CRP) is considered a marker of chronic inflammation and also a mediator of the atherosclerotic process. The purpose of this study is to compare the results of three quantitative immunoturbidimetric method used to measure CRP amounts in patient serum samples in a clinical laboratory. Freshly collected patient serums (n=100) were analyzed with 2 different analyzer (Siemens Advia 1800 and Abbott Architect C 8000) and 3 different reagents (Siemens, Sentinel, Archem). In order to determine whether they provide equivalent results in terms of traceability, the EP09-A3 guideline was used, and comparisons were evaluated within the scope of this standard. Limit of quantification (LoQ), Inter27 assay, Intra-assay, precision studies have been done. The relationship between these three reagents was determined by regression analysis and Bland Altman method. Regression coefficiencies between these three methods were found: ArchemSentinel r2=0,9987, Archem – Siemens r2=0,9986 and Sentinel – Siemens r2=0,9984. Regression equations between Archem-Sentinel y=-0,1359+1.0035x, between Archem-Siemens y=-0,02646+1,002x and between Sentinel – Siemens y=0,1326+0,9978x were found. For the first time in the literature, our results indicated that these three immunoturbidimetric methods were compatible. | |
| dc.identifier.citation | Uca, E., Hacıhasanoğlu Çakmak, N. ve Yiğitbaşı, T. (2024). The comparison between the results of turbidimetric method for c-reactive protein measurement using different instruments. Acta Pharmaceutica Sciencia, 62(4), 778-792. http://dx.doi.org/10.23893/1307-2080.aps6251 | |
| dc.identifier.doi | 10.23893/1307-2080.aps6251 | |
| dc.identifier.endpage | 792 | |
| dc.identifier.issn | 1307-2080 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85207513713 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 778 | |
| dc.identifier.uri | http://dx.doi.org/10.23893/1307-2080.aps6251 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12511/13146 | |
| dc.identifier.volume | 62 | |
| dc.indekslendigikaynak | Scopus | |
| dc.institutionauthor | Uca, Erkan | |
| dc.institutionauthor | Hacıhasanoğlu Çakmak, Neziha | |
| dc.institutionauthor | Yiğitbaşı, Türkan | |
| dc.institutionauthorid | 0009-0007-7989-6004 | |
| dc.institutionauthorid | 0000-0002-6183-5015 | |
| dc.institutionauthorid | 0000-0002-0675-1839 | |
| dc.language.iso | en | |
| dc.relation.ispartof | Acta Pharmaceutica Sciencia | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Archem | |
| dc.subject | CRP | |
| dc.subject | Method Comparison | |
| dc.subject | Sentinel | |
| dc.subject | Siemens | |
| dc.title | The comparison between the results of turbidimetric method for c-reactive protein measurement using different instruments | |
| dc.type | Article |