<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

The comparison between the results of turbidimetric method for c-reactive protein measurement using different instruments

dc.contributor.authorUca, Erkan
dc.contributor.authorHacıhasanoğlu Çakmak, Neziha
dc.contributor.authorYiğitbaşı, Türkan
dc.date.accessioned2025-10-27T09:03:08Z
dc.date.available2025-10-27T09:03:08Z
dc.date.issued2024
dc.departmentİstanbul Medipol Üniversitesi, İMÜ Meslek Yüksekokulu, Tıbbi Laboratuvar Teknikleri Ana Bilim Dalı
dc.departmentİstanbul Medipol Üniversitesi, Sağlık Bilimleri Enstitüsü
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü, Tıbbi Biyokimya Ana Bilim Dalı
dc.description.abstractC-reactive protein (CRP) is considered a marker of chronic inflammation and also a mediator of the atherosclerotic process. The purpose of this study is to compare the results of three quantitative immunoturbidimetric method used to measure CRP amounts in patient serum samples in a clinical laboratory. Freshly collected patient serums (n=100) were analyzed with 2 different analyzer (Siemens Advia 1800 and Abbott Architect C 8000) and 3 different reagents (Siemens, Sentinel, Archem). In order to determine whether they provide equivalent results in terms of traceability, the EP09-A3 guideline was used, and comparisons were evaluated within the scope of this standard. Limit of quantification (LoQ), Inter27 assay, Intra-assay, precision studies have been done. The relationship between these three reagents was determined by regression analysis and Bland Altman method. Regression coefficiencies between these three methods were found: ArchemSentinel r2=0,9987, Archem – Siemens r2=0,9986 and Sentinel – Siemens r2=0,9984. Regression equations between Archem-Sentinel y=-0,1359+1.0035x, between Archem-Siemens y=-0,02646+1,002x and between Sentinel – Siemens y=0,1326+0,9978x were found. For the first time in the literature, our results indicated that these three immunoturbidimetric methods were compatible.
dc.identifier.citationUca, E., Hacıhasanoğlu Çakmak, N. ve Yiğitbaşı, T. (2024). The comparison between the results of turbidimetric method for c-reactive protein measurement using different instruments. Acta Pharmaceutica Sciencia, 62(4), 778-792. http://dx.doi.org/10.23893/1307-2080.aps6251
dc.identifier.doi10.23893/1307-2080.aps6251
dc.identifier.endpage792
dc.identifier.issn1307-2080
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85207513713
dc.identifier.scopusqualityQ3
dc.identifier.startpage778
dc.identifier.urihttp://dx.doi.org/10.23893/1307-2080.aps6251
dc.identifier.urihttps://hdl.handle.net/20.500.12511/13146
dc.identifier.volume62
dc.indekslendigikaynakScopus
dc.institutionauthorUca, Erkan
dc.institutionauthorHacıhasanoğlu Çakmak, Neziha
dc.institutionauthorYiğitbaşı, Türkan
dc.institutionauthorid0009-0007-7989-6004
dc.institutionauthorid0000-0002-6183-5015
dc.institutionauthorid0000-0002-0675-1839
dc.language.isoen
dc.relation.ispartofActa Pharmaceutica Sciencia
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectArchem
dc.subjectCRP
dc.subjectMethod Comparison
dc.subjectSentinel
dc.subjectSiemens
dc.titleThe comparison between the results of turbidimetric method for c-reactive protein measurement using different instruments
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Uca-Erkan-2024.pdf
Size:
618.49 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.17 KB
Format:
Item-specific license agreed upon to submission
Description: