<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

A biomechanical study of locking spongious screws and failure rates are higher than expected in plate fixation

dc.contributor.authorParmaksızoğlu, Fatih
dc.contributor.authorÇetin, Onur
dc.contributor.authorKılıç, Sinan
dc.contributor.authorİnce, Yener
dc.date.accessioned2026-01-30T10:58:34Z
dc.date.available2026-01-30T10:58:34Z
dc.date.issued2025
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Ortopedi ve Travmatoloji Ana Bilim Dalı
dc.description.abstractLocking plates have a rapidly growing process especially in the past decades and results are satisfactory especially in the osteoporotic bones compared to non-locking compression plates. There are many forms of failure in the fracture fixation of locking plates, and screw pull-out is one of the main failure reasons. In this study, we aim to investigate pull-out failure in locking plates using locking spongious screws. The pull-out force of an FDA approved locking plate system (LPS) and anonymous locking plate using the single lead head locking spongious screw (LPuLSS) was evaluated in vitro on the PCF-15 and PCF-10 osteoporotic sawbone models. A total of 28 individual plate-bone models were tested and pull-out force was evaluated on a distraction machine. The moment of separation of the screws from the bone blocks was noted. In the first study using PCF15 bone model, in Group 1, the pull-out force has an average of 606.82 N. In Group 2, the pull-out force has an average of 294.15 N. According to these results, Group 1 adhere to the bone model 206.29% more strongly than those in Group 2 (P = 0.025). In the second study using PCF 10, in Group 3, the average pull-out force was 166.50 N and in Group 4 the average was 42.83 N. According to these results, Group 3 adhere to the bone model 388.74% more strongly than those in Group 4 (P = 0.002). Locking plates are mostly used in osteoporotic bones and this study demonstrated that the single lead head locking spongious screws which is currently used worldwide have a serious technical problem which arouses with difference of the thread pitch distances on the body and on the head causes pull-out failure.
dc.identifier.citationParmaksızoğlu, F., Çetin, O., Kılıç, S. ve İnce, Y. (2025). A biomechanical study of locking spongious screws and failure rates are higher than expected in plate fixation. Scientific Reports, 15(1). http://dx.doi.org/10.1038/s41598-025-87045-0
dc.identifier.doi10.1038/s41598-025-87045-0
dc.identifier.issn2045-2322
dc.identifier.issue1
dc.identifier.pmid39837929
dc.identifier.scopus2-s2.0-85216524238
dc.identifier.scopusqualityQ1
dc.identifier.urihttp://dx.doi.org/10.1038/s41598-025-87045-0
dc.identifier.urihttps://hdl.handle.net/20.500.12511/13399
dc.identifier.volume15
dc.identifier.wosWOS:001403054300029
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorÇetin, Onur
dc.institutionauthorid0000-0002-3986-2527
dc.language.isoen
dc.relation.ispartofScientific Reports
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFracture
dc.subjectLocking Plate
dc.subjectLocking Spongiosus Screw
dc.subjectOsteoporosis
dc.titleA biomechanical study of locking spongious screws and failure rates are higher than expected in plate fixation
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Çetin-Onur-2025.pdf
Size:
1.43 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.17 KB
Format:
Item-specific license agreed upon to submission
Description: