Effect of anti-rotational abutment features and novel computerized fabrication techniques on the marginal fit of implant-supported metal copings

dc.contributor.authorAktaş, Güliz
dc.contributor.authorGüncü, Mustafa Barış
dc.contributor.authorAkçin, Elif Tuba
dc.contributor.authorÇakan, Umut
dc.contributor.authorCanay, Şenay
dc.date.accessioned2021-04-07T06:19:14Z
dc.date.available2021-04-07T06:19:14Z
dc.date.issued2021
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı
dc.description.abstractPurpose An in vitro study to compare the marginal fit of cobalt-chromium (Co-Cr) metal copings fabricated with selective laser melting (SLM), computer-aided design and computer-aided manufacturing (CAD/CAM) milling, and lost-wax (LW) techniques, on abutments with two different antirotational features. Materials and Methods A total of 60 stainless steel abutments with the same length and convergence angles were fabricated using a numerical control machining. Half of the abutments had one flat plane, while the other half had three grooves as an antirotation feature. Thirty abutments of each kind were then divided into three subgroups, and metal copings were fabricated with SLM, CAD/CAM milling, or the LW technique (n = 10). The metal copings were cemented with polycarboxylate cement. Marginal gap measurements were performed using a stereomicroscope at a magnification of x 45 and data were analyzed with two-way analysis of variance (ANOVA) tests. Results The LW (p= 0.002) and CAD/CAM (p< 0.001) techniques exhibited increased marginal gaps on the abutments with a three groove antirotational feature; however, no significant difference was detected with the SLM technique (p= 0.259). The copings fabricated with the SLM technique demonstrated significantly lower gap values in both abutment types (p< 0.001). Conclusion While all marginal gap values were within the clinically acceptable range (<120 mu m), abutments with more antirotational grooves exhibited wider marginal gaps with the LW and CAD/CAM techniques.
dc.identifier.citationAktaş, G., Güncü, M. B., Akçin, E.T., Çakan, U. ve Canay, Ş. (2021). Effect of anti-rotational abutment features and novel computerized fabrication techniques on the marginal fit of implant-supported metal copings. Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry, 30(3), 252-256. https://dx.doi.org/10.1111/jopr.13263
dc.identifier.doi10.1111/jopr.13263
dc.identifier.endpage256
dc.identifier.issn1059-941X
dc.identifier.issn1532-849X
dc.identifier.issue3
dc.identifier.scopusqualityQ1
dc.identifier.startpage252
dc.identifier.urihttps://dx.doi.org/10.1111/jopr.13263
dc.identifier.urihttps://hdl.handle.net/20.500.12511/6705
dc.identifier.volume30
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWiley
dc.relation.ispartofJournal of Prosthodontics-Implant Esthetic and Reconstructive Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectMarginal Fit
dc.subjectImplant Crowns
dc.subjectAbutment Feature
dc.subjectFabrication Technique
dc.titleEffect of anti-rotational abutment features and novel computerized fabrication techniques on the marginal fit of implant-supported metal copings
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Cakan-Umut-2021.pdf
Size:
539.74 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: