Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths

dc.authorid0000-0002-2267-6656
dc.authorid0000-0002-2563-2149
dc.contributor.authorKarabela, Yunus
dc.contributor.authorEliaçık, Mustafa
dc.contributor.authorKaya, Faruk
dc.date.accessioned10.07.201910:49:13
dc.date.accessioned2019-07-10T19:36:21Z
dc.date.available10.07.201910:49:14
dc.date.available2019-07-10T19:36:21Z
dc.date.issued2016
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Göz Hastalıkları Ana Bilim Dalı
dc.descriptionMedical Technologies National Conference, TIPTEKNO 2015 -- 15 October 2015 through 18 October 2015 -- 118954
dc.description.abstractBackground: The SRK/T formula is one of the third generation IOL calculation formulas. The purpose of this study was to evaluate the performance of the SRK/T formula in predicting a target refraction ±1.0D in short and long eyes using ultrasound biometry after phacoemulsification. Methods: The present study was a retrospective analysis, which included 38 eyes with an AL < 22.0 mm (short AL), and 62 eyes ?24.6 mm (long AL) that underwent uncomplicated phacoemulsification. Preoperative AL was measured by ultrasound biometry and SRK/T formula was used for IOL calculation. Three different IOLs were implanted in the capsular bag. The prediction error was defined as the difference between the achieved postoperative refraction, and attempted predicted target refraction. Statistical analysis was performed with SPSS V21. Results: In short ALs, the mean age was 65.13 ± 9.49 year, the mean AL was 21.55 ± 0.45 mm, the mean K1 and K2 were 45.76 ± 1.77D and 46.09 ± 1.61D, the mean IOL power was 23.96 ± 1.92D, the mean attempted (predicted) value was 0.07 ± 0.26D, the mean achieved value was 0.07 ± 0.63 D, the mean PE was 0.01 ± 0.60D, and the MAE was 0.51 ± 0.31D. A significant positive relationship with AL and K1, K2, IOL power and a strong negative relationship with PE and achieved postoperative was found. In long ALs, the mean age was 64.05 ± 7.31 year, the mean AL was 25.77 ± 1.64 mm, the mean K1 and K2 were 42.20 ± 1.57D and 42.17 ± 1.68D, the mean IOL power was 15.79 ± 5.17D, the mean attempted value was -0.434 ± 0.315D, the mean achieved value was -0.42 ± 0.96D, the mean PE was -0.004 ± 0.93D, the MAE was 0.68 ± 0.62D. A significant positive relationship with AL and K1, K2 and a significant positive relationship with PE and achieved value, otherwise a negative relationship with AL and IOL power was found. There was a little tendency towards hyperopic for short ALs and myopic for long ALs. The majority of eyes (94.74 %) for short ALs and (70.97 %) for long ALs were within ±1 D of the predicted refractive error. No significant relationship with PE and IOL types, AL, K1, K2, IOL power, and attempted value, besides with MAE and AL, K1, K2, age, attempted, achieved value were found in both groups. Conclusion: The SRK/T formula performs well and shows good predictability in eyes with short and long axial lengths.
dc.identifier.citationKarabela, Y., Eliaçık, M. ve Kaya, F. (2016). Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths. BMC Ophthalmology, 16(1). https://dx.doi.org/10.1186/s12886-016-0271-8
dc.identifier.doi10.1186/s12886-016-0271-8
dc.identifier.issn1471-2415
dc.identifier.issue1
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://hdl.handle.net/20.500.12511/1139
dc.identifier.urihttps://dx.doi.org/10.1186/s12886-016-0271-8
dc.identifier.volume16
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherBioMed Central Ltd.
dc.relation.ispartofBMC Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsAttribution 4.0 International*
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectCataract Surgery
dc.subjectIOL Power Calculation
dc.subjectLong Axial Length
dc.subjectRefractive Outcome
dc.subjectShort Axial Length
dc.subjectSRK/T
dc.titlePerformance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Karabela-Yunus 2016.pdf
Size:
1.25 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text