CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot study

dc.authorid0000-0002-1753-6747
dc.contributor.authorBilir, Halenur
dc.contributor.authorYüzbaşıoğlu, Emir
dc.contributor.authorSayar, Gülşilay
dc.contributor.authorKılınç, Delal Dara
dc.contributor.authorGözükara Bağ, Harika Gözde
dc.contributor.authorÖzcan, Mutlu
dc.date.accessioned2022-11-16T07:12:45Z
dc.date.available2022-11-16T07:12:45Z
dc.date.issued2022
dc.departmentİstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı
dc.description.abstractPurpose This pilot study was part of a larger study planned for the future which aimed to compare the clinical success of two different resin cements used in the cementation of CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed dentures (RBFPDs). Methods Twenty-four RBFPDs were fabricated with monolithic zirconia (Katana (TM) Zirconia HT, Kuraray Noritake Dental Inc, Tokyo, Japan). Panavia F2.0 (PF2.0; n = 12) and Panavia V5 (PV5; n = 12) were used for cementation. The survival period was defined as the time when the restoration was placed in the mouth and lasted until an irreparable damage occurred. The repairable failures were identified as relative and irreparable failures were identified as absolute failure. The survival rate of the RBFPDs was determined by the Kaplan-Meier estimator. Statistical significance was set at p < 0.05. Results The mean observation times of the PF2.0 group and the PV5 group were 40.45 +/- 6.15 months and 40.18 +/- 6.41 months, respectively. Four failures occurred in the PF2.0 group. No failure was observed in the PV5 group. The curves of survival rate (PF2.0 = 80%, PV5 = 100%) showed no statistically significant difference (p = 0.031), although success rate (PF2.0 = 66.7%, PV5 = 100%) showed statistically significant difference (p = 0.317). Conclusion Up to 40 months mean follow-up period, performance of RBFPDs bonded with PV5 was better than with PF2.0. Clinical Significance For clinicians, it is a matter of hesitation to apply single-retainer RBFPDs. This study contains results of 40 months (minimum 32, maximum 50.47 months) clinical follow-ups of single-retainer RBFPDs. These results will enlighten clinicians about the clinical success of the resin cement type for single-retainer monolithic zirconia ceramic RBFPDs.
dc.identifier.citationBilir, H., Yüzbaşıoğlu, E., Sayar, G., Kılınç, D. D., Gözükara Bağ, H. G. ve Özcan, M. (2022). CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot study. Journal of Esthetic and Restorative Dentistry, 34(7), 1122-1131. https://doi.org/10.1111/jerd.12945
dc.identifier.doi10.1111/jerd.12945
dc.identifier.endpage1131
dc.identifier.issn1496-4155
dc.identifier.issn1708-8240
dc.identifier.issue7
dc.identifier.pmid35920051
dc.identifier.scopus2-s2.0-85135233359
dc.identifier.scopusqualityQ1
dc.identifier.startpage1122
dc.identifier.urihttps://doi.org/10.1111/jerd.12945
dc.identifier.urihttps://hdl.handle.net/20.500.12511/9968
dc.identifier.volume34
dc.identifier.wos000835866300001en_US
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorBilir, Halenur
dc.language.isoen
dc.publisherWiley
dc.relation.ispartofJournal of Esthetic and Restorative Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectCAD/CAM
dc.subjectCeramics
dc.subjectDental Materials
dc.subjectDigital Dentistry
dc.subjectProsthodontics
dc.titleCAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot study
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bilir-Halenur-2022.pdf
Size:
3.96 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: