Intersession intra-rater and inter-rater reliability of myotonometer for upper and lower extremity muscles in children with spinal muscular atrophy
| dc.contributor.author | Kutlutürk Yıkılmaz, Seval | |
| dc.contributor.author | Çevik Saldıran, Tülay | |
| dc.contributor.author | Öztürk, Özgül | |
| dc.contributor.author | Öktem, Sedat | |
| dc.date.accessioned | 2025-10-21T11:32:27Z | |
| dc.date.available | 2025-10-21T11:32:27Z | |
| dc.date.issued | 2024 | |
| dc.department | İstanbul Medipol Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı | |
| dc.description.abstract | Background/Objectives: This study aimed to examine intra- and inter-rater reliability of a myotonometer (MyotonPRO) in measuring upper and lower extremity mechanical properties in children with spinal muscular atrophy types I and II. Methods: Biceps brachii, triceps brachii, rectus femoris, and gastrocnemius muscle tone and stiffness in children (n = 21) were measured using the MyotonPRO device. Examiner 1 performed two sets of measurements in 60 min to determine intra-rater reliability. Examiner 2 performed measurements between Examiner 1’s sets. Intra–interclass correlation coefficient, minimal detectable change, and standard error of measurement values were calculated to assess intra- and inter-rater reliabilities in this cross-sectional study. Results: The results showed excellent intra- and inter-rater reliability analyses for frequency and stiffness values except for the stiffness value of the gastrocnemius muscle, which presented good reliability (ICC = 0.71). Minimal detectable change values ranged from 0.59 to 1.98 Hz for muscle tone and 16.08 to 124.74 N/m for stiffness (for both intra- and inter-rater reliabilities). Conclusions: Our findings indicate that MyotonPRO is a reliable tool for quantifying upper and lower extremity mechanical properties within one session in children with spinal muscular atrophy types I and II. Mechanical properties of the extremity muscle can be determined using this easily applied tool in future studies. | |
| dc.description.sponsorship | Scientific Research Projects Unit of Bitlis Eren University (BEBAP) | |
| dc.identifier.citation | Kutlutürk Yıkılmaz, S., Çevik Saldıran, T., Öztürk, Ö. ve Öktem, S. (2024). Intersession intra-rater and inter-rater reliability of myotonometer for upper and lower extremity muscles in children with spinal muscular atrophy. Diagnostics, 14(20). http://dx.doi.org/10.3390/diagnostics14202300 | |
| dc.identifier.doi | 10.3390/diagnostics14202300 | |
| dc.identifier.issn | 2075-4418 | |
| dc.identifier.issue | 20 | |
| dc.identifier.pmid | 39451623 | |
| dc.identifier.scopus | 2-s2.0-85207486307 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.uri | http://dx.doi.org/10.3390/diagnostics14202300 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12511/13128 | |
| dc.identifier.volume | 14 | |
| dc.identifier.wos | WOS:001341703600001 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.indekslendigikaynak | PubMed | |
| dc.institutionauthor | Öktem, Sedat | |
| dc.language.iso | en | |
| dc.relation.ec | info:eu-repo/grantAgreement/EC/FP7/BEBAP/2021.07 | |
| dc.relation.ispartof | Diagnostics | |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.rights | Attribution 4.0 International | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Muscle Stiffness | |
| dc.subject | Muscle Tone | |
| dc.subject | Myotonometry | |
| dc.subject | Reliability | |
| dc.subject | Spinal Muscular Atrophy | |
| dc.title | Intersession intra-rater and inter-rater reliability of myotonometer for upper and lower extremity muscles in children with spinal muscular atrophy | |
| dc.type | Article |










