<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Evaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the trendelenburg position: a prospective observational study

dc.contributor.authorÖmür, Burak
dc.contributor.authorÇiftçi, Bahadır
dc.contributor.authorKaraaslan, Pelin
dc.date.accessioned2025-09-17T13:28:33Z
dc.date.available2025-09-17T13:28:33Z
dc.date.issued2024
dc.departmentİstanbul Medipol Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
dc.description.abstractBACKGROUND: The Trendelenburg position and pneumoperitoneum may cause cerebral edema and increased intracranial pressure. Noninvasive measurement of the diameter of the optic nerve sheath by ultrasonography can provide early recognition of intracranial pressure. OBJECTIVE: Evaluate the optic nerve sheath diameter (ONSD) changes in patients who undergo laparoscopic surgery in the Trendelenburg position and make indirect conclusions about changes in intracranial pressure. DESIGN: Prospective, observational SETTING: Laparoscopic surgeries PATIENTS AND METHODS: Patients aged 18-75 years who underwent laparoscopic surgery in the Trendelenburg position under general anesthesia were included in our study. The ONSD was measured four times: Immediately after tracheal intubation, in the neutral position (baseline value) (T0), 10 minutes after pneumoperitoneum and Trendelenburg position (T1), 60 minutes after pneumoperitoneum and Trendelenburg position (T2), and 10 minutes after the pneumoperitoneum is terminated and placed in the neutral position (T3). MAIN OUTCOME MEASURES: Compare ONSD measured by ultrasonography at different times of surgery. SAMPLE SIZE: 40 RESULTS: Arterial carbon dioxide pressure increased with laparoscopy and Trendelenburg position in parallel with ONSD measurements and decreased again after returning to the neutral position. It was still higher than the baseline value at the T3. There was also a significant difference[a] between the measurement made at the T2 and the measurement made at T1. This difference showed that the prolongation of the Trendelenburg time was associated with an increase in ONSD. At the end of the operation it was observed that the decreased statistically significantly (T3) 10 minutes after the pneumoperitoneum was terminated and the position was corrected. However, the ONSD was still higher at the end of the operation (T3) compared to the baseline value measured at the beginning of the operation (T0). CONCLUSION: The ONSD increased in relation to Trendelenburg position and pneumoperitoneum. With these results, we think the ultrasonographic measurement of ONSD, a non-invasive method, can be used for clinical follow-up when performing laparoscopic surgery in the Trendelenburg position in cases requiring intracranial pressure monitoring. LIMITATIONS: There may be variations in the measurement of ONSD, even in the measurements of the same practitioner, as in all imaging with an ultrasonography device. CONFLICT OF INTEREST: None.
dc.identifier.citationÖmür, B., Çiftçi, B. ve Karaaslan, P. (2024). Evaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the trendelenburg position: a prospective observational study. Annals of Saudi Medicine, 44(5), 319-328. http://dx.doi.org/10.5144/0256-4947.2024.319
dc.identifier.doi10.5144/0256-4947.2024.319
dc.identifier.endpage328
dc.identifier.issn0256-4947
dc.identifier.issn1319-9226
dc.identifier.issue5
dc.identifier.pmid39368121
dc.identifier.scopus2-s2.0-85205795933
dc.identifier.scopusqualityQ3
dc.identifier.startpage319
dc.identifier.urihttp://dx.doi.org/10.5144/0256-4947.2024.319
dc.identifier.urihttps://hdl.handle.net/20.500.12511/13048
dc.identifier.volume44
dc.identifier.wosWOS:001331171400004
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorÖmür, Burak
dc.institutionauthorÇiftçi, Bahadır
dc.institutionauthorKaraaslan, Pelin
dc.institutionauthorid0000-0002-7241-200X
dc.institutionauthorid0000-0002-3245-6614
dc.institutionauthorid0000-0002-5273-1871
dc.language.isoen
dc.relation.ispartofAnnals of Saudi Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTrendelenburg Position
dc.subjectPneumoperitoneum
dc.subjectAdolescent
dc.subjectIntracranial Hypertension
dc.titleEvaluation of optic nerve sheath diameter in patients undergoing laparoscopic surgery in the trendelenburg position: a prospective observational study
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ömür-Burak-2024.pdf
Size:
704.78 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.17 KB
Format:
Item-specific license agreed upon to submission
Description: