<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Seismic performance of an existing low-rise RC building considering the addition of a new storey

dc.authorid0000-0003-4668-3938
dc.contributor.authorGüneş, Barış
dc.contributor.authorCoşgun, Turgay
dc.contributor.authorSayın, Barış
dc.contributor.authorMangır, Atakan
dc.date.accessioned2020-03-12T10:50:16Z
dc.date.available2020-03-12T10:50:16Z
dc.date.issued2019
dc.departmentİstanbul Medipol Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümü
dc.description.abstractIn low-rise reinforced concrete (RC) buildings, structural design is generally performed considering the seismic effects as well as the vertical loads. However, there may be situations where the additional or unpredicted loads may be encountered during the service life of the buildings. The loads that are governed from a new storey addition during the service life is a good example for these additional loads. Since the reconstruction permits and building height limits specified by the authorities may vary in life-cycle of the structures, it is critical to decide the addition of a storey to an existing building considering the structural safety concerns. In this study, an existing low-rise RC building is modelled with an added storey (subsequently planned for construction), and numerical analyses are carried out considering the extra loads of this additional storey. The aim is to evaluate the seismic performance of the structure considering this unpredicted situation which was not taken into account in the original structural design. The suitability of the preliminary structural design project to the existing building was checked by the site investigations. The results of the numerical analysis were compared with the seismic code requirements, and the seismic performance level of the building is determined. The study is intended to be useful in determining the path to be followed for the determination of the seismic capacity if existing buildings are subjected to additional loads.
dc.identifier.citationGüneş, B., Coşgun, T., Sayın, B. ve Mangır, A. (2019). Seismic performance of an existing low-rise RC building considering the addition of a new storey. Revista de la Construccion, 18(3), 459-475. http://dx.doi.org/10.7764/rdlc.18.3.459
dc.identifier.doi10.7764/RDLC.18.3.459
dc.identifier.endpage475
dc.identifier.issue3
dc.identifier.scopusqualityQ3
dc.identifier.startpage459
dc.identifier.urihttp://dx.doi.org/10.7764/rdlc.18.3.459
dc.identifier.urihttps://hdl.handle.net/20.500.12511/5034
dc.identifier.volume18
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPontificia Universidad Católica de Chile
dc.relation.ispartofRevista de la Construccionen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectRC Buildings
dc.subjectStorey Addition
dc.subjectSeismic Performance
dc.titleSeismic performance of an existing low-rise RC building considering the addition of a new storey
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
mangir-atakan(2019).pdf
Size:
2.07 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: