Temperature rises during tooth bleaching with different light-curing units
| dc.contributor.author | Özyılmaz, Özgün Yusuf | |
| dc.contributor.author | Yavuz, Tevfik | |
| dc.contributor.author | Sarı, Tu?rul | |
| dc.contributor.author | Aykent, Filiz | |
| dc.contributor.author | Öztürk, Atiye Nilgün | |
| dc.date.accessioned | 10.07.201910:49:13 | |
| dc.date.accessioned | 2019-07-10T19:57:15Z | |
| dc.date.available | 10.07.201910:49:13 | |
| dc.date.available | 2019-07-10T19:57:15Z | |
| dc.date.issued | 2015 | |
| dc.department | İstanbul Medipol Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Ana Bilim Dalı | |
| dc.description | WOS: 000354532700005 | |
| dc.description.abstract | The aim of this study was to evaluate the influence of three different light-curing units on the temperature rise induced in the pulpal cavity, when bleached with 35% hydrogen peroxide (HP). Forty extracted maxillary central incisors were randomly divided into four groups according to photoactivation procedure (n=10). Whiteness HP (WHP) bleaching agent which contains 35% HP bleach was placed on the facial tooth surface and no photoactivation device was used (control); an blue light-emitting diode (LED, 40s), a diode laser (4W, Continous mode, 20s), and Nd:YAG laser (4W, 60Hz frequency, 20s). Temperature rise in the pulpal chamber was measured with a J-type thermocouple wire that was connected to a data logger before and immediately after each 20-40s application. One tooth of each group was selected for scanning electron microscope analysis. Data were analyzed using one-way ANOVA followed by the Games Howell post hoc test at a preset alpha of 0.05. One-way ANOVA revealed that there was a significant difference among the light-curing units (p<0.05) and between control group and light-curing units (p<0.05). The Nd:YAG induced significantly, which resulted in higher temperature increase than other light-curing units (10.7 degrees C). The LED unit produced the lowest temperature changes (3.2 degrees C) among the light-curing units. The presence of the bleaching gel did not cause a temperature increase in control group (0 degrees C). The results suggested that using light-curing units caused temperature changes in the intrapulpal cavity during tooth bleaching. The use of LED will be more safer for pulpal health when assisted with WHP bleaching gel. | |
| dc.identifier.citation | Özyılmaz, Ö. Y., Yavuz, T., Sarı, T., Aykent, F. ve Öztürk, A. N. (2015). Temperature rises during tooth bleaching with different light-curing units. Journal of Adhesion Science and Technology, 29(15), 1572-1580. https://dx.doi.org/10.1080/01694243.2015.1035490 | |
| dc.identifier.doi | 10.1080/01694243.2015.1035490 | |
| dc.identifier.endpage | 1580 | |
| dc.identifier.issn | 0169-4243 | |
| dc.identifier.issn | 1568-5616 | |
| dc.identifier.issue | 15 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 1572 | |
| dc.identifier.uri | https://dx.doi.org/10.1080/01694243.2015.1035490 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12511/2934 | |
| dc.identifier.volume | 29 | |
| dc.identifier.wosquality | Q3 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | |
| dc.publisher | Taylor and Francis | |
| dc.relation.ispartof | Journal of Adhesion Science and Technology | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
| dc.rights | info:eu-repo/semantics/embargoedAccess | |
| dc.subject | Light-Curing Units | |
| dc.subject | Laser | |
| dc.subject | Thermocouple | |
| dc.subject | Bleaching | |
| dc.subject | Pulpal Health | |
| dc.title | Temperature rises during tooth bleaching with different light-curing units | |
| dc.type | Article |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- ozyilmaz, ozgun-2015.pdf
- Size:
- 179.91 KB
- Format:
- Adobe Portable Document Format
- Description:
- Tam Metin / Full Text










